Powered by GoogleTranslate

Inspection Detail

Inspection: 102829686 - American Rooftec

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 102829686
Report ID: 0418100
Date Opened: 10/06/1989

Site Address:
American Rooftec
1445 General Arts Road
Conyers, GA 30207

Mailing Address:
P.O. Box 7916, Marietta, GA 30065

Union Status: NonUnion

SIC:1799

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/11/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/15/1990


Related Activity
Type Activity Nr Safety Health
Accident 360414254
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 4 7
Current Violations 3 4 7
Initial Penalty $2,260 $0 $0 $0 $0 $2,260
Current Penalty $1,320 $0 $0 $0 $0 $1,320
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 10/20/1989 10/23/1989 $320 $640 $0 I - Informal Settlement  
2. 01002 Serious 19260416 A01 10/20/1989 10/23/1989 $500 $810 $0 I - Informal Settlement  
3. 01003 Serious 19260416 A03 10/20/1989 10/23/1989 $500 $810 $0 I - Informal Settlement  
4. 02001 Other 19260059 E01 10/20/1989 12/01/1989 $0 $0 $0 -  
5. 02002 Other 19260059 G01 10/20/1989 12/01/1989 $0 $0 $0 -  
6. 02003 Other 19260059 H 10/20/1989 12/01/1989 $0 $0 $0 -  
7. 02004 Other 19260404 B01 I 10/20/1989 10/30/1989 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14337109
Event: 10/05/1989
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU METAL WAND

AN EMPLOYEE WAS SPRAYING WATERPROOFING MATERIAL ONTO THE METAL ROOF OF A BUILDING. A 7200-VOLT OVERHEAD POWER LINE WAS LOCATED NEAR THE ROOF. THE EMPLOYEE ACCIDENTALLY CONTACTED THE POWER LINE WITH THE 2-FOOT-LONG SPRAY WAND AND WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED, ROOFER, METAL PIPE, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102829686 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.