Powered by GoogleTranslate

Inspection Detail

Inspection: 102508975 - West Salem Plastics

Inspection Information - Office: Madison Area Office

 

Inspection Nr: 102508975
Report ID: 0523300
Date Opened: 03/16/1994

Site Address:
West Salem Plastics
600 Brickl Road
West Salem, WI 54669

Mailing Address:
, , 00000

Union Status: Union

SIC:3465

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/10/1994

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 02/12/1996


Related Activity
Type Activity Nr Safety Health
Referral 901547109 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations 3 2 5
Initial Penalty $9,000 $35,000 $0 $0 $0 $44,000
Current Penalty $9,000 $0 $0 $1,200 $0 $10,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100038 A03 I 05/26/1994 06/28/1994 $800 $1,500 $0 06/13/1994 F - Formal Settlement  
2. 01002 Serious 19100107 C06 05/26/1994 07/28/1994 $1,200 $2,500 $0 06/13/1994 F - Formal Settlement  
3. 01003A Other 19101030 D03 II 05/26/1994 05/31/1994 $0 $2,500 $0 06/13/1994 F - Formal Settlement  
4. 01003B Serious 19101030 D04 II 05/26/1994 06/01/1994 $1,200 $0 $0 06/13/1994 F - Formal Settlement  
5. 01003C Serious 19101030 D04 IIIC 05/26/1994 06/01/1994 $0 $0 $0 06/13/1994 F - Formal Settlement  
6. 01004A Other 19101030 F01 IIA 05/26/1994 05/31/1994 $0 $2,500 $0 06/13/1994 F - Formal Settlement  
7. 01004B Other 19101030 F03 05/26/1994 06/01/1994 $0 $0 $0 06/13/1994 F - Formal Settlement  
8. 02001 Serious 19100106 E02 IVC 05/26/1994 06/01/1994 $7,000 $35,000 $0 06/13/1994 F - Formal Settlement  

Investigation Summary

Investigation Nr: 14372577
Event: 03/16/1994
Employee severely burned when vapors ignite

To clean off paint residue, 15 gallons of acetone were spread on a cement floor for use with a Power Boss floor buffer SB22, serial #1000385. A spark ignited vapors, which then exploded. Employee #1 sustained burns over 85 percent of his body. He was hospitalized.

Keywords: BURN, VAPOR, FLAMMABLE VAPORS, CLEANING, ACETONE, EXPLOSION, SPARK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102508975 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close