Powered by GoogleTranslate

Inspection Detail

Inspection: 102305034 - Brown & Root Usa, Inc.

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 102305034
Report ID: 0626600
Date Opened: 12/07/1988

Site Address:
Brown & Root Usa, Inc.
2800 Decker Drive (Exxon)
Baytown, TX 77522

Mailing Address:
P.O. Box 3, Houston, TX 77001

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/13/1989

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/13/1989


Related Activity
Type Activity Nr Safety Health
Accident 360345573

Investigation Summary

Investigation Nr: 14219067
Event: 12/06/1988
ONE KILLLED AND TWO HOSPITALIZED-FIRE IN AKLY UNIT OF EXXON

Two Exxon employees were hospitalized from burns and one was killed as a result of a fire in the akly unit during a shutdown. The cause of the fire was a result of releasing hydrocarbons into the sewer system.

Keywords: BURN, SEWER, CHEMICAL BURN, POISONING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102305034 Fatality Burn(Chemical) Occupation not reported
2 102305034 Hospitalized injury Burn(Chemical) Occupation not reported
3 102305034 Hospitalized injury Burn(Chemical) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.