Inspection: 102074689 - Albright & Wilson, Inc.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 102074689
Report ID: 0454510
Date Opened: 12/13/1985

Site Address:
Albright & Wilson, Inc.
2151 King Street Ext.
Charleston, SC 29405

Mailing Address:
, , 00000

Union Status: Union

SIC:2869

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/16/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/22/1986


Related Activity
Type Activity Nr Safety Health
Accident 360777247
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 01/21/1986 02/24/1986 $350 $350 $0 02/13/1986 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 734624
Event: 12/12/1985
EMPLOYEES BURNED WHEN PHOSPHOROUS WAS SPLASHED ON THEM

EMPLOYEES #1 AND #2 WERE ASSIGNED THE TASK OF REPLACING A FLANGE AND A VALVE IN THE P4 STORAGE TANK AREA. EMPLOYEE #2 WAS WEARING A NOMEX SUIT BUT EMPLOYEE #2 WAS NOT WEARING ANY TYPE OF PPE. THE PLAN WAS FOR EMPLOYEE #2 TO DO THE ACTUAL WORK WHILE EMPLOYEE #1 STOOD BY WITH A HALF INCH WATER HOSE IN CASE ANY PROBLEMS DEVELOPED. A NIPPLE CONNECTION ON THE LINE BEHIND EMPLOYEE #1 SUDDENLY RUPTURED, SPRAYING THE AREA WITH PHOSPHOROUS. THE NIPPLE WAS 3 INCHES LONG. EMPLOYEES #3 AND #4, WERE ALSO IN THE AREA AND WERE SPRAYED WITH PHOSPHOROUS. SINCE PHOSPHOROUS IGNITES WHEN IT COMES IN CONTACT WITH AIR, THE SPRAYED EMPLOYEES SUFFERED MINOR BURNS. EMPLOYEE #3 ALSO SUFFERED A CUT ON HIS ELBOW AS HE WAS SCRAMBLING TO GET AWAY FROM THE SPRAYING PHOSPHOROUS.

Keywords: BURN, MAINTENANCE, FIRE, PHOSPHOROUS, RUPTURE, LACERATION, HIGH PRESSURE, PIPE, ELBOW

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 102074689 Non Hospitalized injury Burn(Chemical) Supervisors, mechanics and repairers
2 102074689 Non Hospitalized injury Burn(Chemical) Supervisors, mechanics and repairers
3 102074689 Non Hospitalized injury Cut/Laceration Miscellaneous plant and system operators
4 102074689 Non Hospitalized injury Burn(Chemical) Supervisors, mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.