Powered by GoogleTranslate

Inspection Detail

Inspection: 101965218 - Cox Manufacturing Co., Inc.

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 101965218
Report ID: 0551800
Date Opened: 06/23/1986

Site Address:
Cox Manufacturing Co., Inc.
108 W. 2nd St.
Ridgeville, IN 47380

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3585

NAICS: 0 


Inspection Type: Planned

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/25/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/02/1987


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $120 $0 $0 $0 $0 $120
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100217 C01 I 07/16/1986 08/18/1986 $120 $240 $0 08/21/1986 F - Formal Settlement  
2. 01001B Serious 19100217 B03 I 07/16/1986 08/18/1986 $0 $0 $0 08/21/1986 -  
3. 02001 Other 19100217 E01 I 07/16/1986 08/18/1986 $0 $0 $0 08/21/1986 -  
4. 02002 Other 19100217 E01 II 07/16/1986 08/18/1986 $0 $0 $0 08/21/1986 -  
5. 02003 Other 19101200 E01 07/16/1986 08/18/1986 $0 $0 $0 08/21/1986 -  

Investigation Summary

Investigation Nr: 670869
Event: 06/23/1986
Employee's thumb pinched between dies

At approximately 2:30 p.m. on May 30, 1986, Employee #1 was used his fingers to place a 2 1/2 inch diameter part disc on the curve of the lower die in a 15 ton Federal full revolution mechanical power press. The dog that engages the flywheel broke, letting the press run continuously. There were approximately 2 inches between the upper die and the part. The upper die came down on his thumb, pinning it. The part did not set in the lower die, allowing the operator time to recut and pull his thumb out. He sustained a skinned thumb, loss of the nail, and mangled skin on the end of the thumb. He was hospitalized for treatment. The press was being used without a point of operation guard and no single control mechanism.

Keywords: DIE, POWER PRESS, PINNED, WORK RULES, THUMB, CAUGHT BETWEEN, PRESS, UNGUARDED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101965218 Hospitalized injury Bruise/Contus/Abras Physician's assistants
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close