Powered by GoogleTranslate

Inspection Detail

Inspection: 101826071 - Calibron, Incorporated

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 101826071
Report ID: 0420600
Date Opened: 07/24/1986

Site Address:
Calibron, Incorporated
2950 Lake Emma Road
Lake Mary, FL 32746

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/29/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 05/12/1988


Related Activity
Type Activity Nr Safety Health
Accident 360146914
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $490 $0 $0 $0 $0 $490
Current Penalty $490 $0 $0 $0 $0 $490
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 09/19/1986 09/24/1986 $490 $490 $0 -  
2. 02001 Other 19040008 09/19/1986 09/24/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14346894
Event: 07/21/1986
ELECTRIC SHOCK - DEFECTIVE ATTACHMENT PLUG

AN EMPLOYEE WAS INSTALLING EQUIPMENT IN AN AREA BETWEEN A TEMPERATURE CONTROL UNIT (AEC MODEL NO. TCW-1) AND AN INJECTION MOLDING MACHINE (VAN DORN MODEL NO. 200 RS14F). THE KEYED PRONG FOR THE GROUNDED CONDUCTOR OF THE PORTABLE TEMPERATURE CONTROL UNIT HAD BEEN MODIFIED SO THAT THE PLUG COULD BE INSERTED INTO THE RECEPTACLE IN ANY POSITION. AT THE TIME OF THE ACCIDENT, THE PLUG WAS INSERTED SO THAT THE PRONG FOR THE GROUNDED CONDUCTOR WAS IN THE SLOT INTENDED FOR THE UNGROUNDED CONDUCTOR. WHEN THE EMPLOYEE CONTACTED THE ENERGIZED FRAME OF THE TEMPERATURE CONTROL UNIT AND THE GROUNDED INJECTION MOLDING MACHINE, HE WAS ELECTROCUTED.

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, GROUND FAULT, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101826071 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close