Powered by GoogleTranslate

Inspection Detail

Inspection: 101303998 - Concrete Company Of Springfield

Inspection Information - Office: Kansas City Area Office

 

Inspection Nr: 101303998
Report ID: 0728500
Date Opened: 08/11/1988

Site Address:
Concrete Company Of Springfield
1802 Melville Road
Springfield, MO 65802

Mailing Address:
510 Sherman, Springfield, MO 65802

Union Status: Union

SIC:1771

NAICS: 0 


Inspection Type: Unprog Rel

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/01/1988

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/03/1989


Related Activity
Type Activity Nr Safety Health
Accident 360354070
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $940 $0 $0 $0 $0 $940
Current Penalty $300 $0 $0 $0 $0 $300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 09/26/1988 08/09/1989 $300 $300 $0 10/13/1988 J - ALJ Decision  
2. 01002 Serious 19260600 A06 09/26/1988 09/29/1988 $640 $640 $0 10/13/1988 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 14505259
Event: 08/08/1988
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

A CONCRETE PUMPER TRUCK CONCRETE PLACEMENT FIRM WAS DELIVERING CONCRETE TO A DRAINAGE DITCH. THE CONCRETE TRUCK OPERATOR WAS USING THE TRUCK'S BOOM EXTENDED OVER A ROAD TO POUR THE CONCRETE. TWO EMPLOYEES OF A DIFFERENT CONCRETE COMPANY WERE HANDLING THE HOSE AT THE END OF THE BOOM TO DIRECT THE PLACEMENT OF THE CONCRETE. THE BOOM CONTACTED A 7620-VOLT OVERHEAD POWER LINE. THE TWO EMPLOYEES HOLDING THE HOSE RECEIVED ELECTRIC SHOCKS. ONE OF THEM WAS ELECTROCUTED; THE OTHER RECEIVED SEVERE BURNS AND WAS HOSPITALIZED IN CRITICAL CONDITION.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CONCRETE TRUCK, E GI IA, TRUCK BOOM, BOOM, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101303998 Fatality Electric Shock Occupation not reported
2 101303998 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close