Powered by GoogleTranslate

Inspection Detail

Inspection: 101286177 - Ltv Steel Company

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 101286177
Report ID: 0522300
Date Opened: 05/27/1987

Site Address:
Ltv Steel Company
3341 Jennings Rd.
Cleveland, OH 44109

Mailing Address:
3100 East 45th Street, Cleveland, OH 44127

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 07/22/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/22/1987


Related Activity
Type Activity Nr Safety Health
Accident 360684229

Investigation Summary

Investigation Nr: 14522726
Event: 05/26/1987
EMPLOYEE KILLED IN MOLTEN METAL EXPLOSION

WHEN THE BASIC OXYGEN FURNACE WAS IN THE TAPPING OR POURING MODE A SERIES OF EXPLOSIONS OCCURRED. THE FURNACE REFRACTORY FAILED, ALLOWING THE MOLTEN METAL TO BURN THROUGH THE SHELL INTO THE TRUNNION WATER JACKET. THERE WERE SEVERAL EXPLOSIONS WHEN THE MOLTEN METAL CONTACTED THE WATER. IN THE TAPPING MODE THE CHARGING OPENING IS ANGLED TOWARD THE SECOND FLOOR, WHERE THE PULPIT HOUSING IS LOCATED. THE FURNACE OPERATION IS CONTROLLED FROM THE PULPIT HOUSING. THE EXPLOSIONS FORCED MOLTEN METAL OUT THE CHARGING OPENING AND ONTO THE SECOND FLOOR, TOWARD THE PULPIT OPENING. THE MOLTEN METAL ENTERED THE PULPIT THROUGH A SIDE DOOR AND IMMEDIATELY IGNITED AN ELECTRICAL FIRE. EMPLOYEE #1 WAS FOUND, DEAD, INSIDE THE PULPIT NEXT TO A DOOR OPPOSITE THE SIDE WHERE THE MOLTEN METAL ENTERED. EMPLOYEE #1 DIED OF THIRD DEGREE BURNS AND SMOKE INHALATION.

Keywords: BURN, FURNACE, EXPLOSION, MOLTEN METAL, SMOKE INHALATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101286177 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.