Powered by GoogleTranslate

Inspection Detail

Inspection: 101238335 - Monsanto Company

Inspection Information - Office: Cincinnati Area Office

 

Inspection Nr: 101238335
Report ID: 0522000
Date Opened: 11/21/1988

Site Address:
Monsanto Company
River Rd.
Addyston, OH 45001

Mailing Address:
, , 00000

Union Status: Union

SIC:2821

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/23/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 06/07/1990


Related Activity
Type Activity Nr Safety Health
Accident 360648000
Referral 901114447 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 3 3
Initial Penalty $3,240 $0 $0 $0 $0 $3,240
Current Penalty $1,480 $0 $0 $0 $0 $1,480
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01002 Serious 19100132 A 01/13/1989 04/23/1990 $540 $900 $0 02/07/1989 F - Formal Settlement  
2. 01003 Serious 19100307 B 01/13/1989 04/19/1990 $400 $900 $0 02/07/1989 F - Formal Settlement  
3. 02001 Serious 5A0001 01/17/1989 01/23/1989 $900 $900 $0 02/07/1989 F - Formal Settlement Citation has been deleted.
4. 02002A Serious 19100132 A 01/13/1989 04/19/1990 $540 $540 $0 02/07/1989 F - Formal Settlement  
5. 02002B Serious 19100134 A01 01/13/1989 04/19/1990 $0 $0 $0 02/07/1989 F - Formal Settlement  
6. 02002C Serious 19101200 H02 III 01/13/1989 04/19/1990 $0 $0 $0 02/07/1989 F - Formal Settlement  

Investigation Summary

Investigation Nr: 869024
Event: 11/19/1988
Employee dies after burned in hopper dust explosion

Employee #1 was cleaning prex hopper #13. He opened the door to put a drop light inside. Laying the light on the bottom of the hopper, he then used a water hose to hose down the inside of the hopper. Because the light didn't have a guard, the bulb was exposed. Water hitting and breaking the bulb caused a dust explosion. Employee #1 suffered burns over 30 percent of his body. Ten days later, Employee #1 died. The light was approved for use in a class II hazardous location.

Keywords: BURN, CLEANING, LIGHTING FIXTURE, EXPLOSION, COMBUSTIBLE DUST, HOPPER, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101238335 Fatality Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.