Powered by GoogleTranslate

Inspection Detail

Inspection: 101210318 - Wadsworth Building Components, Inc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 101210318
Report ID: 0419700
Date Opened: 08/28/1987

Site Address:
Wadsworth Building Components, Inc.
U.S. 1 North
Bunnell, FL 32010

Mailing Address:
P.O. Box 638, Bunnell, FL 32010

Union Status: NonUnion

SIC:2439

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/02/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/06/1988


Related Activity
Type Activity Nr Safety Health
Accident 360143390
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 3 5
Current Violations 2 3 5
Initial Penalty $840 $0 $0 $0 $0 $840
Current Penalty $420 $0 $0 $0 $0 $420
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 09/30/1987 10/09/1987 $210 $420 $0 I - Informal Settlement  
2. 01002 Serious 19100178 L 09/30/1987 10/09/1987 $210 $420 $0 I - Informal Settlement  
3. 02001 Other 19101200 E01 09/30/1987 10/30/1987 $0 $0 $0 -  
4. 02002 Other 19101200 G08 09/30/1987 10/30/1987 $0 $0 $0 -  
5. 02003 Other 19101200 H 09/30/1987 10/30/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14354278
Event: 08/27/1987
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU FORKLIFT

AN EMPLOYEE WAS OPERATING A CATERPILLAR ROUGH TERRAIN INDUSTRIAL FORKLIFT TRUCK (MODEL NUMBER R-80) TO MOVE WOOD ROOF TRUSSES TO THE TRUCK LOADING AREA OF A PLANT. THE TRUSSES BEING MOVED WERE OF AN UNUSUAL SIZE, FORCING THE FORKLIFT OPERATOR TO EXTEND THE MAST OF THE FORKLIFT TRUCK TO ITS FULL HEIGHT (ABOUT 20 FEET, 10 INCHES). AS THE OPERATOR TURNED THE LIFT AROUND TO MANEUVER AROUND THE STORED TRUSSES, THE MAST OF THE FORKLIFT CONTACTED A 7620-VOLT OVERHEAD POWER LINE AND ITS NEUTRAL. THE PHASE CONDUCTOR HAD BEEN INSTALLED AT A HEIGHT OF ABOUT 20 FEET, 9 INCHES, AND THE NEUTRAL HAD BEEN INSTALLED AT A HEIGHT OF ABOUT 18 FEET, 7.5 INCHES. APPARENTLY, THE OPERATOR TRIED TO EXIT THE TRUCK AND WAS ELECTROCUTED.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E GI IA, INDUSTRIAL TRUCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101210318 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.