Powered by GoogleTranslate

Inspection Detail

Inspection: 101107530 - Anderson Steel Erectors, Inc.

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 101107530
Report ID: 0830500
Date Opened: 02/25/1992

Site Address:
Anderson Steel Erectors, Inc.
Airport Office Bldg., New Denver Int. Airport
Denver, CO 80294

Mailing Address:
4830 Van Gordon Street, Wheat Ridge, CO 80033

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/06/1992

Emphasis: L:Fall

Case Closed: 01/27/1994


Related Activity
Type Activity Nr Safety Health
Accident 360455349
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 2 2
Initial Penalty $21,000 $0 $0 $0 $0 $21,000
Current Penalty $10,000 $0 $0 $0 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/07/1992 12/01/1993 $5,000 $7,000 $0 08/27/1992 F - Formal Settlement  
2. 01002 Serious 5A0001 08/07/1992 12/01/1993 $5,000 $7,000 $0 08/27/1992 F - Formal Settlement  
3. 01003 Serious 19260550 B02 08/07/1992 08/07/1992 $7,000 $7,000 $0 08/27/1992 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 930727
Event: 02/25/1992
Two iron workers killed in fall from structural steel

At approximately 2:40 p.m. on February 25, 1992, Employees #1 and #2, iron workers, were working on the steel erection of section 2a of the airport office building at the Denver International Airport construction site in Denver, CO. The two workers were connecting a steel beam to a steel column on the seventh level of the building. One worker was seated on the beam that was being connected to the column, while the other worker was standing at the base of the column, at the top of a sheer concrete wall. The base of the column was secured to the concrete wall by temporary welds to an embedded steel plate. When the crew had a problem connecting the beam to the structural steel column, a determination was made by the steel erecting crew to pull the top of the column 1 in. to the north to facilitate the connection. The pull was performed by tensioning a cable guy, using a come-along, by applying a fork at the column being connected, and by using a sleeper. While one employee was seated on the beam, the temporary welds at the column base fractured. The column collapsed, and Employees #1 and #2 fell to their death.

Keywords: COLUMN, CONCUSSION, BROKEN WELD, FALL, FALL PROTECTION, IRON WORKER, WORK RULES, STEEL CONNECTING, CONSTRUCTION, STEEL ERECTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 101107530 Fatality Concussion Occupation not reported
2 101107530 Fatality Concussion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.