Powered by GoogleTranslate

Inspection Detail

Inspection: 100678853 - C F & I Steel Corp.

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 100678853
Report ID: 0830500
Date Opened: 04/05/1990

Site Address:
C F & I Steel Corp.
225 Canal Street
Pueblo, CO 81002

Mailing Address:
P.O. Box 316, Pueblo, CO 81002

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/02/1990

Emphasis:

Case Closed: 09/12/1990


Related Activity
Type Activity Nr Safety Health
Referral 901373142 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 2 6
Current Violations 1 2 3
Initial Penalty $2,410 $0 $0 $0 $0 $2,410
Current Penalty $200 $0 $0 $0 $0 $200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/09/1990 09/10/1990 $1,000 $1,000 $0 I - Informal Settlement Citation has been deleted.
2. 01002 Other 19100036 B04 08/09/1990 09/10/1990 $0 $420 $0 I - Informal Settlement  
3. 01003 Serious 19100303 F 08/09/1990 09/10/1990 $200 $640 $0 I - Informal Settlement  
4. 01004 Serious 19100305 B02 08/09/1990 09/10/1990 $350 $350 $0 I - Informal Settlement Citation has been deleted.
5. 02001 Other 19100151 B 08/09/1990 09/10/1990 $0 $0 $0 I - Informal Settlement Citation has been deleted.
6. 02002 Other 19100305 B02 08/09/1990 09/10/1990 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14430391
Event: 04/05/1990
Employee burned in furnace explosion

Employee #1 was checking where water was leaking into an electric arc furnace. When the water came in contact with the hot steel, there was an explosion and hot slag and molten metal spewed out onto Employee #1. He was hospitalized as a result of his injuries.

Keywords: FURNACE, LEAK, PPE, MOLTEN SLAG, WORK RULES, EXPLOSION, MOLTEN METAL, STRUCK BY, HIGH TEMPERATURE, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100678853 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close