Powered by GoogleTranslate

Inspection Detail

Inspection: 100358241 - Atlantic Steel Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 100358241
Report ID: 0418100
Date Opened: 01/22/1986

Site Address:
Atlantic Steel Company
1300 Meceslin Street, Nw
Atlanta, GA 30318

Mailing Address:
P.O. Box 1714, Atlanta, GA 30301

Union Status: Union

SIC:3312

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 01/24/1986

Emphasis:

Case Closed: 03/17/1986


Related Activity
Type Activity Nr Safety Health
Accident 360172845
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $630 $0 $0 $0 $0 $630
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/07/1986 04/09/1986 $630 $630 $0 A - Amendment Citation has been deleted.

Investigation Summary

Investigation Nr: 14332530
Event: 01/16/1986
FURNACE UNDER REPAIR EXPLODED, EMPLOYEES INJURED

EMPLOYEE #1 WAS A FURNACE OPERATOR. EMPLOYEES #2 AND #3 WERE REPAIRMEN WORKING ON A FURNACE PART. WHEN THE FURNACE ACCIDENTALLY FILLED WITH WATER, EMPLOYEE #1 OPERATED THE FURNACE CONTROLS TO TIP IT AND LET THE WATER RUN OUT THE TAP HOLD. THE OTHER TWO EMPLOYEES WATCHED. THE FURNACE SUDDENLY EXPLODED, INFLICTING SERIOUS INJURY TO THE 3 MEN. EMPLOYEE #1 WAS HOSPITALIZED FOR 6 WEEKS AND DIED AFTER BEING RELEASED FROM THE HOSPITAL BURN UNIT. EMPLOYEE #2 IS RECOVERING AT HOME AFTER 8 WEEK'S HOSITALIZATION. EMPLOYEE #3 WAS HOSPITALIZED FOR A FEW DAYS AND HAS RETURNED TO REGULAR EMPLOYMENT.

Keywords: BURN, FURNACE, REPAIR, EXPLOSION, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 100358241 Fatality Burn/Scald(Heat) Occupation not reported
2 100358241 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 100358241 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close