Inspection Detail
Inspection: 100213677 - Joseph Ruffa
Inspection Information - Office: Long Island Area Office
Site Address:
Joseph Ruffa
1225 Hawthorne Drive East
Wantagh, NY 11793
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:1795
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/08/1987
Emphasis:
Case Closed: 01/18/1989
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $160 | $0 | $0 | $0 | $0 | $160 |
| Current Penalty | $160 | $0 | $0 | $0 | $0 | $160 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260850 E | 04/09/1987 | 04/12/1987 | $160 | $160 | $0 | - |
Investigation Summary
EMPLOYEE #1 WAS WALKING IN A BUILDING WHEN A HALON FIRE EXTINGUISHING TANK BEGAN EJECTING GAS AND BECAME A FLYING MISSILE. THE TANK STRUCK EMPLOYEE #1 IN THE LEG. IT HAS NOT BEEN DETERMINED WHAT CAUSED THE TANK TO BEGIN RELEASING GAS.
Keywords: FIRE EXTINGUISHER, STRUCK BY, FLYING OBJECT, LEG
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 100213677 | Occupation Not Listed |