Accident Report Detail
Accident: 14391742 - Employee Injured In Refinery Explosion And Fire
Accident: 14391742 -- Report ID: 0625700 -- Event Date: 03/03/1991 | |||||||
Inspection | Open Date | SIC | Establishment Name | ||||
---|---|---|---|---|---|---|---|
110416880 | 03/04/1991 | 2911 | Citgo Petroleum Corporation-Lcmc | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
110416872 | 03/04/1991 | 1791 | Otis Elevator Co., Inc. | ||||
Inspection | Open Date | SIC | Establishment Name | ||||
110416831 | 03/04/1991 | 1629 | International Maintenace Corp. | ||||
On March 3, 1991, the "A" catalyne cracking unit at the Citgo Petroleum Corporation's Lake Charles Refinery was being brought back on line after a seven-week turnaround. At approximately 2:00 p.m., the oil feed had been started. At approximately 11:00 p.m. an explosion and fire occurred. Employee #1 was injured. | |||||||
Keywords:
explosion, maintenance, flammable liquid, fire, construction, oil line, refinery
| |||||||
Employee # | Inspection | Age | Sex | Degree | Nature | Occupation | |
1 | 110416880 | Occupation Not Listed | |||||
2 | 110416872 | Hospitalized injury | Burn(Chemical) | Occupation not reported | |||
3 | 110416831 | Occupation Not Listed |