Inspection Detail
Inspection: 953074.015 - Hunter Hauling, Llc
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Hunter Hauling, Llc
526 S Lavaca
Moulton, TX 77975
Mailing Address:
1048 Texan Trail, Grapevine, TX 76051
Union Status: NonUnion
SIC:
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/17/2013
Emphasis: L:Oilgas
Case Closed: 07/16/2014
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 865727 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $19,600 | $0 | $0 | $0 | $0 | $19,600 |
| Current Penalty | $14,700 | $0 | $0 | $0 | $0 | $14,700 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100146 C04 | 06/13/2014 | 07/08/2014 | $0 | $4,900 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 19100146 D04 I | 06/13/2014 | 07/08/2014 | $4,900 | $4,900 | $0 | I - Informal Settlement | ||
| 3. | 01003 | Serious | 19100146 D04 II | 06/13/2014 | 07/08/2014 | $4,900 | $4,900 | $0 | I - Informal Settlement | ||
| 4. | 01004 | Serious | 19100146 E01 | 06/13/2014 | 07/08/2014 | $4,900 | $4,900 | $0 | I - Informal Settlement |
Investigation Summary
At 11:15 a.m. on December 17, 2013, an employee was assisting a welder to repair a leak on a tank. The tank was located on the bed of a tractor trailer. The employee entered the tank to hold a patch in place while the welder remained on the outside. As the welder applied the welding torch to the tank, an explosion occurred. The employee was ejected approximately 75 feet from the tank and was killed. The incident investigation determined that flammable gases were present in the tank that led to the explosion.
Keywords: Confined Space, Ejected, Explosion, Flammable Vapors
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 953074.015 | 45 | M | Fatality | Laborers, except construction |
Translate