Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 950705.015 - Precision Concrete Pumping, Inc.

Inspection Information - Office: Albany Area Office

 

Inspection Nr: 950705.015
Report ID: 0213100
Date Opened: 12/02/2013

Site Address:
Precision Concrete Pumping, Inc.
918 Homestead Avenue
Maybrook, NY 12543

Mailing Address:
1 Prospect Avenue, Albany, NY 12206

Union Status: NonUnion

SIC:

NAICS: 238110/Poured Concrete Foundation and Structure Contractors


Inspection Type: Fat/Cat

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/02/2013

Emphasis:

Case Closed: 05/02/2014


Related Activity
Type Activity Nr Safety Health
Accident 864991
Inspection 950658 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 55330.015
Event: 12/02/2013
Employee is struck by collapsing concrete formwork and is ki

At 12:15 p.m. on December 2, 2013, Employee #1 was pouring concrete into the form. The formwork did not hold the weight of the concrete and collapsed, striking, and killing the employee.

Keywords: Concrete, Concrete Form Work, Fracture, Struck By, Structural Collapse

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 950705.015 51 M Fatality Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close