Inspection Detail
Inspection: 901394.015 - Childers Roofing & Sheet Metal, Inc.
Inspection Information - Office: Savannah Area Office
Site Address:
Childers Roofing & Sheet Metal, Inc.
1131 Chapel Crossing Building 680
Brunswick, GA 31525
Mailing Address:
141 Watts St, Jacksonville, FL 32204
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 04/17/2013
Emphasis: L:Fall
Case Closed: 10/22/2014
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 814247 | ||
| Inspection | 910110 | Yes | |
| Inspection | 910117 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $8,250 | $0 | $15,400 | $0 | $0 | $23,650 |
| Current Penalty | $13,500 | $0 | $0 | $0 | $0 | $13,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260754 E02 II | 09/12/2013 | 10/01/2013 | $3,500 | $4,400 | $0 | 10/07/2013 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19260760 D01 | 09/12/2013 | 10/01/2013 | $3,000 | $3,850 | $0 | 10/07/2013 | F - Formal Settlement | |
| 3. | 01003 | Serious | 19260503 C | 09/12/2013 | 10/01/2013 | $7,000 | $15,400 | $0 | 10/07/2013 | F - Formal Settlement |
Investigation Summary
At 11:15 a.m. on April 15, 2013, an employee was pulling a tape measure to get a measurement of the length of the roof panel. While walking from the roof ridge toward the north side of the roofd, the employee walked onto an area where a section of the metal roof had been cut, in preparation for its removal. The cut metal section was about 4 feet wide by 8 feet long and was laying on some horizontal perlins. The employee stepped on the cut metal roof section and one end of the roof panel flipped upward causing the employee to fall through the roof opening to the concretre floor below. The employee sustained multiple fractures to the upper body and internal injuries. The employee was killed from the impact with the concrete floor.
Keywords: Fall, Fall Protection, Roof, Steel Erection, Unguarded, Unguarded Fl Opening
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 901394.015 | 48 | M | Fatality | Roofers |