Powered by GoogleTranslate

Inspection Detail

Inspection: 897280 - Enamel Products & Plating Company

Inspection Information - Office: Pittsburgh Area Office

 

Inspection Nr: 897280
Report ID: 0317500
Date Opened: 11/19/1986

Site Address:
Enamel Products & Plating Company
3500 Walnut Street
Mckeesport, PA 15132

Mailing Address:
P.O. Box 159, Mckeesport, PA 15134

Union Status: Union

SIC:3479

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/26/1986

Emphasis:

Case Closed: 02/05/1987


Related Activity
Type Activity Nr Safety Health
Accident 360505531
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $2,430 $0 $0 $0 $0 $2,430
Current Penalty $2,430 $0 $0 $0 $0 $2,430
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 12/16/1986 02/16/1987 $630 $630 $0 I - Informal Settlement  
2. 01002 Serious 5A0001 12/16/1986 02/16/1987 $900 $900 $0 I - Informal Settlement  
3. 01003 Serious 5A0001 12/16/1986 02/16/1987 $900 $900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14470140
Event: 11/19/1986
One killed, two injured in fall when work table collapses

Employees #1 through #3 were standing on a table, changing the separator rolls on a 60 in. slitter. The table was supported in a horizontal position by a hydraulic cylinder and ram, which were located under the table and the forward section. The separator roll slipped from the slitter helper's hand and fell into the machine, breaking the hydraulic connection to the cylinder and ram that supported the table. This caused a loss of hydraulic pressure and the table dropped into the pit. Employee #1 fell 25 ft into the pit and was killed. Employee #2 also fell, but caught a handrail and climbed out of the pit. He injured his back, but was not hospitalized. Employee #3 was pinned by the hinged arm of the table under the equipment where the separator roll was located; he was hospitalized. The table had no safety stop, safety leg, or other safety devices in its hydraulic system.

Keywords: COLLAPSE, PINNED, WORK RULES, HYDRAULIC LINE, HYDRAULIC TABLE, FALL, SLITTER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 897280 Fatality Fracture Occupation not reported
2 897280 Non Hospitalized injury Strain/Sprain Occupation not reported
3 897280 Hospitalized injury Fracture Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close