Powered by GoogleTranslate

Inspection Detail

Inspection: 759332 - Primex Plastics Corporation

Inspection Information - Office: Hasbrouck Heights Area Office

 

Inspection Nr: 759332
Report ID: 0214500
Date Opened: 09/12/1988

Site Address:
Primex Plastics Corporation
65 River Drive
Garfield, NJ 07026

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3089

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/05/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/23/1989


Related Activity
Type Activity Nr Safety Health
Accident 360659882
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 2 7
Current Violations 5 2 7
Initial Penalty $1,780 $0 $0 $0 $0 $1,780
Current Penalty $1,400 $0 $0 $0 $0 $1,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 10/12/1988 02/15/1989 $640 $640 $0 I - Informal Settlement  
2. 01002 Serious 19100133 A01 10/12/1988 10/15/1988 $120 $240 $0 I - Informal Settlement  
3. 01003 Serious 19100213 H01 10/12/1988 12/15/1988 $180 $300 $0 I - Informal Settlement  
4. 01004 Serious 19100213 H04 10/12/1988 12/15/1988 $160 $300 $0 I - Informal Settlement  
5. 01005 Serious 19100303 G02 I 10/12/1988 10/31/1988 $300 $300 $0 -  
6. 02001 Other 19101200 E01 I 10/12/1988 02/15/1989 $0 $0 $0 I - Informal Settlement  
7. 02002 Other 19101200 H 10/12/1988 02/15/1989 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 14491690
Event: 09/10/1988
ELECTRIC SHOCK - UNKNOWN CAUSE

AN EMPLOYEE WAS PERFORMING MAINTENANCE ON A CORD- AND PLUG-CONNECTED, 240-VOLT, ELECTRICALLY HEATED, PLASTIC EXTRUSION DIE. THE EMPLOYEE WAS ELECTROCUTED AS HE WAS WORKING ON THIS EQUIPMENT. (THE REPORT DID NOT STATE THE CAUSE OF THE ACCIDENT.)

Keywords: MAINTENANCE, ELECTRICAL, E GI VII, ELECTROCUTED, ELEC EQUIPMENT--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 759332 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.