Powered by GoogleTranslate

Inspection Detail

Inspection: 738583 - Durabond Company

Inspection Information - Office: Pittsburgh Area Office

 

Inspection Nr: 738583
Report ID: 0317500
Date Opened: 02/08/1988

Site Address:
Durabond Company
2658 Jefferson Street
Export, PA 15632

Mailing Address:
Box Drawer 518, Export, PA 15632

Union Status: NonUnion

SIC:3479

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/08/1988

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/14/1988


Related Activity
Type Activity Nr Safety Health
Referral 901008771 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $180 $0 $0 $0 $0 $180
Current Penalty $180 $0 $0 $0 $0 $180
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100219 E01 I 03/03/1988 03/16/1988 $180 $180 $0 -  
2. 01001B Serious 19100219 F03 03/03/1988 03/16/1988 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14326946
Event: 02/08/1988
4 EMPLOYEES BURNED WHEN COAL TAR VAPORS IGNITED

EMPLOYEES #1-4 WERE WORKING AROUND A COAL TAR PITCH TANK THAT CONTAINED COAL TAR PITCH HEATED TO ABOUT 450 DEGREES FAHRENHEIT. THE MATERIAL PRODUCES EXTREMELY FLAMMABLE VAPORS AT THAT TEMPERATURE. THE TANK HAS A LARGE COVER ON IT WITH A DOOR TO ADD COAL TAR PITCH. THE COVER IS NOT BOLTED OR OTHERWISE SECURED TO THE TANK. A 2 INCH STEEL PIPE IS PUMPED FULL OF COAL TAR PITCH FROM THE BOTTOM OF THE TANK. THE PIPE RUNS 65 FEET IN BOTH DIRECTIONS AND RETURNS TO A CONNECTING PART ON THE COVER. EMPLOYEES #1-4 WERE CHANGING THE SECTION OF PIPE THAT GOES INTO THE COVER. THE INLET WAS OPEN. EMPLOYEE #1 INADVERTENTLY PASSED A TORCH ACROSS THE INLET. THE VAPORS IGNITED. THEY WERE ALL STANDING NEXT TO THE TANK AND WERE BURNED BY FLAMES SHOOTING OUT FROM BETWEEN THE TANK AND ITS COVER.

Keywords: BURN, COAL TAR PITCH, FLAMMABLE VAPORS, WORK RULES, FIRE, TORCH, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 738583 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close