Inspection Detail
Inspection: 725341 - Stewart Industrial Services, Inc.
Inspection Information - Office: Charleston Area Office
Site Address:
Stewart Industrial Services, Inc.
Philip Sporn Power Plant, Route 33
New Haven, WV 25265
Mailing Address:
Post Office Box 674, St. Clairsville, OH 43950
Union Status: NonUnion
SIC:1721
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/1987
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 08/21/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360659130 |
Investigation Summary
Employee #1 was spraying a coat of flammable urethane on the inside of a 7 ft high by 6 ft diameter metal tank. The vapors ignited and exploded while he was leaving the tank. Employee #1 was killed.
Keywords: VAPOR, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, EXPLOSION, CHEMICAL VAPOR, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 725341 | Fatality | Electric Shock | Occupation not reported |