Powered by GoogleTranslate

Inspection Detail

Inspection: 651430 - Ncr Corporation, Microelectronics Division

Inspection Information - Office: Denver Area Office

 

Inspection Nr: 651430
Report ID: 0830500
Date Opened: 10/07/1985

Site Address:
Ncr Corporation, Microelectronics Division
1635 Aeroplaza Drive
Colorado Springs, CO 80916

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3674

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/04/1986

Emphasis:

Case Closed: 05/20/1986


Related Activity
Type Activity Nr Safety Health
Accident 360633812
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $240 $0 $0 $0 $0 $240
Current Penalty $240 $0 $0 $0 $0 $240
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100038 A05 III 04/07/1986 05/12/1986 $240 $240 $0 -  
2. 01001B Serious 19100134 B08 04/07/1986 05/12/1986 $0 $0 $0 -  
3. 02001 Other 19100132 A 04/07/1986 06/02/1986 $0 $0 $0 -  
4. 02002A Other 19100134 B01 04/07/1986 05/12/1986 $0 $0 $0 -  
5. 02002B Other 19100134 B03 04/07/1986 05/12/1986 $0 $0 $0 -  
6. 02002C Other 19100134 B11 04/07/1986 05/01/1986 $0 $0 $0 -  
7. 02002D Other 19100134 E03 04/07/1986 06/02/1986 $0 $0 $0 -  
8. 02002E Other 19100134 E05 I 04/07/1986 05/12/1986 $0 $0 $0 -  
9. 02002F Other 19100134 E05 I 04/07/1986 05/12/1986 $0 $0 $0 -  
10. 02002G Other 19100134 F02 II 04/07/1986 05/12/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14506612
Event: 10/03/1985
EMPLOYEES EXPOSED TO PHOSPHINE GAS

THE AFFECTED EMPLOYEES WERE EXPOSED TO PHOSPHINE GAS DURING THE OPERATION OF AN ION IMPLANTER. THE GASES FROM INSIDE THE VACUUM CHAMBER WERE EMITTED INTO THE WORK ENVIRONMENT BECAUSE THE VENTILATION CONNECTION ON THE VACUUM PUMP WAS NOT ATTACHED TO THE VENTILATION SYSTEM.

Keywords: RESPIRATORY, VENTILATION, INHALATION, PHOSPHINE GAS, TOXIC FUMES

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
2 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
4 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
5 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
6 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
7 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
8 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
9 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
10 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
11 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
12 651430 Hospitalized injury Poisoning(Systemic) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close