Inspection Detail
Inspection: 650853 - C F & I Steel, Inc.
Inspection Information - Office: Denver Area Office
Site Address:
C F & I Steel, Inc.
Abriendo & Canal Sts
Pueblo, CO 81002
Mailing Address:
P.O. Box 316, Pueblo, CO 81002
Union Status: Union
SIC:3312
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/20/1985
Emphasis:
Case Closed: 12/24/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360634026 |
Investigation Summary
AN ELECTRIC ARC FURNACE EXPLODED, THROWING AN ENORMOUS AMOUNT OF DUST INTO THE AIR. AS A RESULT, NINE EMPLOYEES WERE SENT TO THE HOSPITAL. ALL NINE EMPLOYEES WERE TREATED AND RELEASED THE SAME DAY.
Keywords: FURNACE, ELECTRIC ARC, DUST, INHALATION, EXPLOSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 2 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 3 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 4 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 5 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 6 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 7 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 8 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported | ||
| 9 | 650853 | Hospitalized injury | Asphyxia | Occupation not reported |
Translate