Powered by GoogleTranslate

Inspection Detail

Inspection: 643494 - Gregorian, Inc.

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 643494
Report ID: 0830300
Date Opened: 02/10/1986

Site Address:
Gregorian, Inc.
East Highway 12
Lemmon, SD 57638

Mailing Address:
P. O. Box 209, Lemmon, SD 57638

Union Status: NonUnion

SIC:3499

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/11/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/07/1986


Related Activity
Type Activity Nr Safety Health
Accident 360633580
Complaint 71332647 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19100212 A03 II 02/26/1986 05/15/1986 $0 $0 $0 P - Petition to Mod Abatement  
2. 01001B Other 19100212 A05 02/26/1986 03/28/1986 $0 $0 $0 -  
3. 01002 Other 19100213 I01 02/26/1986 03/28/1986 $0 $0 $0 -  
4. 01003A Other 19100217 B04 I 02/26/1986 03/28/1986 $0 $0 $0 -  
5. 01003B Other 19100217 C02 IA 02/26/1986 03/28/1986 $0 $0 $0 -  
6. 01003C Other 19100217 C02 IB 02/26/1986 05/15/1986 $0 $0 $0 P - Petition to Mod Abatement  
7. 01004A Other 19100219 B01 02/26/1986 03/28/1986 $0 $0 $0 -  
8. 01004B Other 19100219 C02 I 02/26/1986 03/28/1986 $0 $0 $0 -  
9. 01004C Other 19100219 C04 I 02/26/1986 05/15/1986 $0 $0 $0 P - Petition to Mod Abatement  
10. 01004D Other 19100219 D01 02/26/1986 03/28/1986 $0 $0 $0 -  
11. 01004E Other 19100219 E03 I 02/26/1986 03/28/1986 $0 $0 $0 -  
12. 01004F Other 19100219 O02 I 02/26/1986 03/28/1986 $0 $0 $0 -  
13. 01004G Other 19100242 B 02/26/1986 03/28/1986 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14535462
Event: 01/30/1986
EMPLOYEES EXPOSED TO CARBON MONOXIDE FROM ANNEALING OVEN

AN ANNEALING OVEN, FUELED BY PROPANE GAS, WAS LIT BY THE COMPANY. AFTER THE OVEN HAD RUN WITHOUT INCIDENT FOR 13-14 HOURS, EMPLOYEE #1 BECAME ILL FROM APPARENT EXPOSURE TO CARBON MONOXIDE. HE WAS SENT TO THE LOCAL CLINIC, WHERE HE WAS KEPT OVERNIGHT. MANAGEMENT ADVISED ANY OTHER EMPLOYEES WHO FELT ILL TO ALSO GO TO THE CLINIC. EMPLOYEES #2 THROUGH #7 DID VISIT THE CLINIC, BUT WERE IMMEDIATELY RELEASED AND RETURNED TO DUTY.

Keywords: OVEN, TOXIC ATMOSPHERE, INHALATION, EXHAUST FUMES, LP GAS, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 643494 Non Hospitalized injury Asphyxia Occupation not reported
2 643494 Non Hospitalized injury Asphyxia Occupation not reported
3 643494 Non Hospitalized injury Asphyxia Occupation not reported
4 643494 Non Hospitalized injury Asphyxia Occupation not reported
5 643494 Non Hospitalized injury Asphyxia Occupation not reported
6 643494 Hospitalized injury Asphyxia Occupation not reported
7 643494 Non Hospitalized injury Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close