Powered by GoogleTranslate

Inspection Detail

Inspection: 3348695 - J. S. Hayes Building Supply Inc.

Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114

 

Inspection Nr: 3348695
Report ID: 0355114
Date Opened: 08/07/1985

Site Address:
J. S. Hayes Building Supply Inc.
8520 Leesburg Pike
Vienna, VA 22180

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5211

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/09/1985

Emphasis:

Case Closed: 08/09/1985


Related Activity
Type Activity Nr Safety Health
Accident 360604854

Investigation Summary

Investigation Nr: 14443873
Event: 08/16/1985
FORK LIFT OVERTURNED, CRUSHING EMPLOYEE

ON AUGUST 16, 1985 AT APPROXIMATELY 4 PM, EMPLOYEE #1 WAS DRIVING A FORKLIFT TRUCK IN THE YARD AREA. HE WAS OPERATING THE TRUCK IN AN UNSAFE MANNER; MAKING SHARP TURNS AT A HIGH RATE OF SPEED. THE FORKLIFT FINALLY OVERTURNED ONTO HIM. HE HAD BEEN INSTRUCTED TO STAY OFF THE FORKLIFTS, BUT DID NOT DO AS HE WAS TOLD. THERE WERE NO WITNESSES TO THE ACCIDENT.

Keywords: SPEEDING, WORK RULES, CRUSHED, INDUSTRIAL TRUCK, HORSEPLAY, OVERTURN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3348695 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close