Powered by GoogleTranslate

Inspection Detail

Inspection: 3335890 - Best Plastering Inc.

Inspection Information - Office: Va-E-Roanoke (Regional Office) -Safety 0355118

 

Inspection Nr: 3335890
Report ID: 0355118
Date Opened: 01/15/1992

Site Address:
Best Plastering Inc.
South Boston Community Hospital
South Boston, VA 24592

Mailing Address:
1401 C Diggs Drive, Raleigh, NC 27603

Union Status: NonUnion

SIC:1742

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/14/1992

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 09/18/2002


Related Activity
Type Activity Nr Safety Health
Accident 360298319
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $1,000 $20,000 $0 $0 $0 $21,000
Current Penalty $1,000 $20,000 $0 $0 $0 $21,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious ELEC0410 05/14/1992 05/19/1992 $1,000 $1,000 $0 06/18/1992 1 - State Lower Court  
2. 02001 Willful ELEC040801II 05/14/1992 05/19/1992 $10,000 $10,000 $0 06/18/1992 1 - State Lower Court  
3. 02002 Willful ELEC0409 B 05/14/1992 05/19/1992 $10,000 $10,000 $0 06/18/1992 1 - State Lower Court  

Investigation Summary

Investigation Nr: 953828
Event: 01/13/1992
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU SCAFFOLD

THREE EMPLOYEES WERE MOVING A RUSTGO WORK PLATFORM. TWO OF THE EMPLOYEES WERE PUSHING AND THE THIRD WAS PULLING THE SCAFFOLD TO A NEW STORAGE LOCATION. THE TEMPERATURE WAS 50 DEGREES FAHRENHEIT; THE WEATHER WAS OVERCAST; AND THE GROUND WAS DAMP FROM AN OVERNIGHT RAIN. AS THE EMPLOYEES WERE MOVING THE SCAFFOLD, THE WORK PLATFORM'S UPRIGHT, WHICH WAS ABOUT 25.67 FEET HIGH, CONTACTED A 7200-VOLT OVERHEAD POWER LINE LOCATED ABOUT 23.75 FEET ABOVE THE GROUND. ONE OF THE EMPLOYEES PUSHING THE SCAFFOLD WAS ELECTROCUTED. THE OTHER TWO EMPLOYEES RECEIVED ELECTRIC SHOCKS. THE ONE THAT WAS ALSO PUSHING WAS HOSPITALIZED FOR HIS INJURY.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, MOBILE SCAFFOLD, ELECTROCUTED, ELECTRIC SHOCK, E GI IB, SCAFFOLD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3335890 Hospitalized injury Electric Shock Supervisors; painters, paperhangers and plasterers
2 3335890 Fatality Electric Shock Plasterers
3 3335890 Non Hospitalized injury Electric Shock Plasterers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.