Powered by GoogleTranslate

Inspection Detail

Inspection: 3330644 - C & V Utilities, Inc.

Inspection Information - Office: Va-E-Norfolk (Regional Office) - Health 03551124

 

Inspection Nr: 3330644
Report ID: 0355124
Date Opened: 10/20/1987

Site Address:
C & V Utilities, Inc.
700 Block Of London Blvd. & Green Street
Portmouth, VA 23704

Mailing Address:
1805 Benefit Road, Chesapeake, VA 23322

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 03/23/1988

Emphasis:

Case Closed: 04/22/1988


Related Activity
Type Activity Nr Safety Health
Referral 900315763 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations
Initial Penalty $480 $0 $0 $0 $0 $480
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 510001 A 03/24/1988 04/25/1988 $240 $240 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Serious 19260021 B06 I 03/24/1988 04/18/1988 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01002 Serious 19260021 B02 03/24/1988 04/18/1988 $240 $240 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 14442834
Event: 10/20/1987
EXPLOSION IN UTILITY TUNNEL INJURES EMPLOYEE

CONSTRUCTION WORK IN A UTILITY TUNNEL HAD BEEN UNDERWAY FOR SEVEN DAYS. NO PROBLEMS HAD BEEN ENCOUNTERED. NO EXPLOSION METER WAS USED TO DETECT FLAMMABLE GASES. ON THE LAST DAY OF THE JOB EMPLOYEE #1 OPENED THE MANHOLE COVER AS USUAL, AND WAS PREPARING TO ENTER THE TUNNEL. AS HE WAS SITTING ON THE SIDE OF THE MANHOLE HE DECIDED TO TAKE A SMOKE BREAK. WHEN HE LIT THE CIGARETTE AN EXPLOSION OCCURRED. HE RECEIVED SECOND DEGREE BURNS OVER 25% OF HIS BODY, FOR WHICH HE WAS HOSPITALIZED FOR TEN DAYS. SUSEQUENT INVESTIGATION REVEALED THAT THE TUNNEL CONTAINED NATURAL GAS (2%), APPARENTLY LEAKING FROM AN ADJACENT TUNNEL.

Keywords: BURN, FLAMMABLE VAPORS, WORK RULES, CONSTRUCTION, NATURAL GAS, EXPLOSION, SMOKING, MANHOLE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3330644 Hospitalized injury Burn/Scald(Heat) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.