Powered by GoogleTranslate

Inspection Detail

Inspection: 3316973 - The Disston Company

Inspection Information - Office: Virginia Central 0355100

 

Inspection Nr: 3316973
Report ID: 0355119
Date Opened: 07/21/1987

Site Address:
The Disston Company
U S 29 N Of
Danville, VA 24543

Mailing Address:
P. O. Box 3000, Danville, VA 24543

Union Status: NonUnion

SIC:3425

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/30/1987

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 11/20/1987


Related Activity
Type Activity Nr Safety Health
Complaint 70150669 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 5 7
Current Violations 2 5 7
Initial Penalty $490 $0 $0 $0 $0 $490
Current Penalty $490 $0 $0 $0 $0 $490
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100022 C 08/19/1987 09/21/1987 $350 $350 $0 -  
2. 01002 Serious 19100215 A01 08/19/1987 08/24/1987 $140 $140 $0 -  
3. 02001 Other 19100110 B06 VI 08/19/1987 08/24/1987 $0 $0 $0 -  
4. 02002 Other 19100110 D10 08/19/1987 09/21/1987 $0 $0 $0 -  
5. 02003 Other 19100110 H12 08/19/1987 08/24/1987 $0 $0 $0 -  
6. 02004 Other 19100212 A01 08/19/1987 08/24/1987 $0 $0 $0 -  
7. 02005 Other 19100252 C06 08/19/1987 09/21/1987 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14225064
Event: 07/21/1987
EMPLOYEE'S FINGERS AMPUTATED WHEN CAUGHT IN POWER PRESS

At approximately 7:30 a.m., on April 24, 1987, Employee #1 was being trained to operate a full revolution Minster power press Serial Number 10-4-4585. The power press was operated by a foot control and equipped with pull back devices. The supervisor of Employee #1 adjusted the pull back devices to fit Employee # 1. When placing a part in the press, Employee # 1 pushed the foot switch and the press cycled. The pull back device of left hand did not pull the hand out, causing partial amputation of four fingers on the left hand. The inspection of the press conducted after the accident found that the bolt holding back frame to the press broke. This allowed the frame to drop or pull away from the press, making the left pull back device too long to pull the hand out of the dies.

Keywords: PULL BACK DEVICE, DIE, AMPUTATED, POWER PRESS, FINGER, FOOT CONTROL, BOLT, HAND

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3316973 Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.