Inspection Detail
Inspection: 3311248 - Westinghouse Electric Corp
Inspection Information - Office: Va-E-Abingdon (Field Office) - Safety 0355110
Site Address:
Westinghouse Electric Corp
Westinghouse Rd
Abingdon, VA 24210
Mailing Address:
Po Box 869, Abingdon, VA 24210
Union Status: Union
SIC:3357
NAICS: 0
Inspection Type: Planned
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/17/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 06/17/1985
Investigation Summary
Employee #1 was working in the CMCR department and required a handheld electric/hydraulic shear to cut a hot copper BPR. According to Employee #1 and the employer's first accident report, a short in the electrical system of the shear allowed the shear knife to operate, cutting off Employee #1's little finger at the first joint.
Keywords: AMPUTATED, SHEAR, FINGER, WORK RULES, MECH MALFUNCTION, UNGUARDED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3311248 | Hospitalized injury | Amputation | Molding and casting machine operators |
Translate