Inspection Detail
Inspection: 3286606 - Prescott Towers Ltd.
Inspection Information - Office: Vt Department Of Labor - Vosha
Site Address:
Prescott Towers Ltd.
Malletts Bay Avenue
Colchester, VT 05446
Mailing Address:
Rr#3, Box 4948, Rutland, VT 05701
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/23/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/23/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360602031 |
Investigation Summary
A 415' RADIO TOWER WAS BEING ERECTED IN A SWAMP. ONE OF THE THREE TIEDOWN ANCHORS, SPACED 120' APART AND 280' FROM THE TOWER BASE, FAILED WHILE EMPLOYEES #1 AND #2 WERE ON THE TOWER AND TIED OFF AT 220' AND 240' ELEVATIONS RESPECTIVELY. BOTH EMPLOYEES, AFTER RIDING THE TOWER DOWN, DIED ON IMPACT OF MULTIPLE BLUNT TRAUMA. TWO 100' HIGH-STRENGTH WIRE STRAND CABLES (.6"7-WIRE), PROTRUDING 6' FROM A MINI-CAISSON (5 1/2" CASING) DRILLED AT 38' FROM THE HORIZONTAL, WERE NOT IN CONTINUOUS LENGTHS. A PROTRUDING 6' TIEDOWN CABLE PULLED OUT OF A "SUPREME" ONE-TIME-USING (OUT) SPLICE CHUCK #S740 LOCATED JUST 6" INSDE OF CASING. BOTH CABLES WERE TESTED AT 125% OF THE DESIGN LOAD SIMULTANEOUSLY RATHER THAN INDEPENDENTLY. TOWER ERECTION AND ANCHOR INSTALLATION PERFORMED BY SEPARATE CONTRACTORS.
Keywords: ERECTION PROCESS, COLLAPSE, CONSTRUCTION, STEEL ERECTION, FALL, TOWER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3286606 | Fatality | Other | Construction trades, n.e.c. | ||
| 2 | 3286606 | Fatality | Other | Construction trades, n.e.c. |
Translate