Powered by GoogleTranslate

Inspection Detail

Inspection: 3275708 - Amax Magnesium Division

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 3275708
Report ID: 0854910
Date Opened: 12/20/1984

Site Address:
Amax Magnesium Division
Rowley Utah 31 Miles No West Of
Grantsville, UT 84029

Mailing Address:
238 North 2200 West, Salt Lake City, UT 84116

Union Status: Union

SIC:3339

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/04/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 07/01/2016


Related Activity
Type Activity Nr Safety Health
Accident 360600498
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other GEN001402 01/15/1985 01/30/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14456149
Event: 12/19/1984
EXPLOSION OF FOUNDRY FURNACE; BURNED BY MOLTEN MAGNESIUM

EMPLOYEE #1 WAS TRANSFERRING MOLTEN MAGNESIUM FROM FURNACE #2 TO FURNACE #3, USING A TRANSFER PUMP AND TRANSFER LINE. THE LINE WAS 1.5 INCHES IN DIAMETER. THE TEMPERATURE IN FURNACE #2 WAS 1238 DEGREES. THE TEMPERATURE IN FURNACE #3 WAS 1125 DEGREES. THE MOLTEN MAGNESIUM HAD JUST STARTED TO TRANSFER INTO THE OTHER FURNACE WHEN THERE WAS AN EXPLOSION. THE TRANSFER LINE WAS BLOWN APPROXIMATELY 50 FEET AWAY. A SMALL AMOUNT OF MOLTEN MAGNESIUM WAS BLOWN ONTO EMPLOYEE #1. THE MOLTEN MAGNESIUM MELTED HIS FACE SHIELD AND INFLICTED SECOND AND THIRD DEGREE BURNS ON HIS FACE, NECK AND CHEST. THE TRANSFER LINE WAS SECURED TO THE TRANSFER PUMP BY SIX STRANDS OF 18 GUAGE WIRE. THE LINE AND PUMP HAD BEEN PREHEATED TO A HIGHER TEMPERATURE THAN THAT OF THE MOLTEN MAGNESIUM BEFORE THEY WERE PLACED IN THE FURNACE. BOTH AND HAD BEEN INSPECTED AND USED SEVERAL HOURS BEFORE THE ACCIDENT.

Keywords: BURN, CHEST, FURNACE, EXPLOSION, MOLTEN METAL, NECK, FOUNDRY, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3275708 Hospitalized injury Burn/Scald(Heat) Furnace, kiln and oven operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.