Inspection Detail
Inspection: 3270394 - Lloyds Fleet Specialists
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Lloyds Fleet Specialists
2000 Industrial Circle
Slc, UT 84104
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:7532
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/26/1985
Emphasis:
Case Closed: 07/01/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360600795 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $240 | $0 | $0 | $0 | $0 | $240 |
| Current Penalty | $240 | $0 | $0 | $0 | $0 | $240 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | GEN01340101 | 03/29/1985 | 04/15/1985 | $120 | $120 | $0 | - | ||
| 2. | 01001B | Serious | GEN01340201 | 03/29/1985 | 04/15/1985 | $0 | $0 | $0 | - | ||
| 3. | 01001C | Serious | GEN01340205 | 03/29/1985 | 04/15/1985 | $0 | $0 | $0 | - | ||
| 4. | 01001D | Serious | GEN01340206 | 03/29/1985 | 04/15/1985 | $0 | $0 | $0 | - | ||
| 5. | 01002 | Serious | GEN01060561 | 03/29/1985 | 04/15/1985 | $120 | $120 | $0 | - | ||
| 6. | 02001 | Other | GEN001103 | 03/29/1985 | 04/15/1985 | $0 | $0 | $0 | - |
Investigation Summary
EMPLOYEE #1 WAS PAINTING THE INSIDE OF THE TANK OF A 5,000 GALLON AIRPLANE REFUELING TRUCK. HE WAS SPRAYING A C-36 THERMOGUARD EPOXY COATING WHICH HAS A MINIMUM FLASH POINT OF 36 DEGREES FAHRENHEIT. EMPLOYEE #1 WAS PAINTING WITH A 2-QUART SPRAY GUN AND USING A DROP LIGHT FOR ILLUMINATION WITHIN THE TANK. THE TWO HATCHES ON THE TOP OF THE TANK WERE OPEN, BUT NO MECHANICAL VENTILATION WAS BEING USED. AN UNDETERMINED IGNITION SOURCE IGNITED THE PAINT VAPORS AND A FIRE ERUPTED. EMPLOYEE #1 WAS BURNED OVER 39.5 PERCENT OF HIS BODY (15.5 PERCENT OF THESE BURNS WERE 3RD DEGREE).
Keywords: BURN, VENTILATION, CONFINED SPACE, FIRE, SPRAY PAINTING, EXPLOSION, COATING OPERATION, LIGHTING, FUEL TRUCK, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3270394 | Hospitalized injury | Burn/Scald(Heat) | Automobile body and related repairers |
Translate