Inspection Detail
Inspection: 3269818 - Sign Pro
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Sign Pro
2050 S Main
Bountiful, UT 84010
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3993
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/07/1985
Emphasis:
Case Closed: 07/01/2016
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | GEN01340205 | 05/15/1985 | 06/10/1985 | $0 | $0 | $0 | - | ||
| 2. | 01002 | Other | GEN01340206 | 05/15/1985 | 06/10/1985 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS OPERATING THE CRANE BOOM ON A SIGN TRUCK. IT WAS A HYDRAULIC JUNIOR GOLIATH CRANE MADE BY GARLAND. AS HE WAS LIFTING A SIGN UP TO A BUILDING, THE EMPLOYEE WAS SUDDENLY SPRAYED BY BURNING HYDRAULIC FLUID. HE RECEIVED SECOND AND THIRD DEGREE BURNS ON HIS BACK AND ON THE TRICEP AREA OF BOTH ARMS. THE INVESTIGATION WHICH FOLLOWED FOUND THAT THE PRESSURE HOSE HAD BEEN ROUTED IN SUCH A MANNER THAT IT RUBBED ACROSS THE TERMINALS OF THE PUMP MOTOR. IT FINALLY CHAFED THROUGH TO THE METAL BRAID, CAUSING AN ELECTRIC ARC, WHICH BURNED THE BRAID. THE HOSE RUPTURED AND THE ARC IGNITED THE ATOMIZED FLUID.
Keywords: BURN, ELECTRIC ARC, ELECTRICAL, CRANE BOOM, TRUCK CRANE, E GI VII, FIRE, HYDRAULIC FLUID, HOSE, HYDRAULIC CRANE
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3269818 | Hospitalized injury | Burn/Scald(Heat) | Construction trades, n.e.c. |