Powered by GoogleTranslate

Inspection Detail

Inspection: 3209442 - Chattahoochie Cable Company

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 3209442
Report ID: 0454510
Date Opened: 06/11/1985

Site Address:
Chattahoochie Cable Company
4800 North Ocean Drive
North Myrtle Beach, SC 29582

Mailing Address:
P. O. Box 4416, Marietta, GA 30061

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/30/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 12/02/1985


Related Activity
Type Activity Nr Safety Health
Accident 360776587
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $350 $0 $0 $0 $0 $350
Current Penalty $350 $0 $0 $0 $0 $350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260400 C01 08/13/1985 08/16/1985 $350 $350 $0 -  
2. 01001B Serious 19260100 A 08/13/1985 08/16/1985 $0 $0 $0 -  
3. 02001 Other 30008 08/13/1985 08/16/1985 $0 $0 $0 -  
4. 02002 Other 19260050 C 08/13/1985 09/16/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14215313
Event: 06/04/1985
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD POWER LINE

THREE EMPLOYEES WERE INSTALLING CABLE TELEVISION CABLE. EACH OF THEM WAS ON A DIFFERENT UTILITY POLE. ONE OF THE EMPLOYEES WAS ABOUT 22.5 FEET UP A 30-FOOT POLE. HE WAS STANDING ON THE TELEPHONE CABLE HOISTING THE TELEVISION CABLE TO A HOOK THAT WAS ABOUT 1 FOOT, 10 INCHES BENEATH AN ELECTRIC TRANSFORMER FOR AN OVERHEAD POWER LINE. THE EMPLOYEE, WHO WAS NOT WEARING A HARD HAT, LEANED HIS HEAD BACK AND CONTACTED THE 7200-VOLT POWER LINE WHILE HE WAS STILL HOLDING THE CABLE. CARDIOPULMONARY RESUSCITATION WAS PERFORMED TO NO AVAIL; THE EMPLOYEE DIED OF ELECTROCUTION.

Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, TELECOM WORK, COMMUNICATION CABLE, CPR, E TC, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3209442 Fatality Electric Shock Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close