Inspection Detail
Inspection: 3189156 - Allied Automotive-Bcbcd Sumter Plant
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Allied Automotive-Bcbcd Sumter Plant
Corporated Way-Sumter Ind. Park
Sumter, SC 29150
Mailing Address:
P. O. Box 2488, Sumter, SC 29150
Union Status: NonUnion
SIC:3714
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/01/1985
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/10/1985
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360776454 |
Investigation Summary
EMPLOYEE #1 WAS WORKING NEAR A DIPTANK CONTAINING 100 GALLONS OF BLACK GLASS ENAMEL (FREEZING POINT, MINUS 27 DEGREES FAHRENHEIT). THE EMPLOYEE'S JOB WAS TO REMOVE PARTS WHICH HAD FALLEN FROM THE CONVEYOR INTO THE DIP TANK. EMPLOYEE #1 WAS STANDING APPROXIMATELY TWO FEET FROM THE OPEN DOOR OF THE DIP TANK. PAINT WAS DRIPPING ONTO THE FLOOR WHILE EMPLOYEE #1 REMOVED PARTS. A LARGE WELDER WAS BEING USED ABOUT 45 FEET AWAY FROM THE DIP TANK. A SPARK FROM THE WELDER SHOT OVER TO THE DIP TANK, IGNITING THE FLAMMABLE VAPORS FROM THE GLASS ENAMEL. EMPLOYEE #1 RECEIVED MINOR BURNS TO HIS BACK AND ARMS FROM THE FLASH FIRE WHICH ERUPTED.
Keywords: BURN, FLAMMABLE VAPORS, FIRE, WELDING, BACK, EXPLOSION, SPARK, ARM
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3189156 | Non Hospitalized injury | Burn(Chemical) | Supervisors, cleaning and building service workers |
Translate