Inspection Detail
Inspection: 3176849 - Aee Tecnica Vega Baja
Inspection Information - Office: Pr-E-Arecibo 0257210
Site Address:
Aee Tecnica Vega Baja
Carr 2 Calle Betances Final
Vega Baja, PR 00693
Mailing Address:
Po Box 364267, San Juan, PR 00936
Union Status: Union
SIC:4911
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: StateGovt
Safety/Health: Safety
Close Conference: 03/17/1987
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/21/1997
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360109862 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 6A0001 | 03/25/1987 | 03/29/1987 | $0 | $0 | $0 | 05/05/1987 | D - Govt Dismissed | Citation has been deleted. |
Investigation Summary
A LINEMAN WAS WORKING NEAR A 4800-VOLT OVERHEAD POWER LINE. HE LAID ONE HAND ON THE THE METAL STRUCTURE OF A SUBSTATION AND THE OTHER HAND ON THE POWER LINE. HE WAS ELECTROCUTED.
Keywords: ELEC PROTECT EQUIP, OVERHEAD POWER LINE, ELECTRICAL, POWER LINE WORKER, ELECTROCUTED, E PTD, SUBSTATION, ELEC UTILITY WORK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3176849 | Fatality | Electric Shock | Supervisors; electricians & power transm. install. |