Inspection Detail
Inspection: 317541134 - La City General Services
Inspection Information - Office: Los Angeles District Office
Site Address:
La City General Services
111 E. First St., 7th Flr.
Los Angeles, CA 90012
Mailing Address:
111 E. First St., Rm. 306-A, Los Angeles, CA 90012
Union Status: Union
SIC:9199
NAICS: 921190/Other General Government Support
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Safety
Close Conference: 07/10/2014
Emphasis:
Case Closed: 08/24/2017
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102890639 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 4 | 5 | |||
Current Violations | 1 | 4 | 5 | |||
Initial Penalty | $3,375 | $0 | $0 | $2,240 | $0 | $5,615 |
Current Penalty | $2,250 | $0 | $0 | $1,310 | $0 | $3,560 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3314 G | 07/11/2014 | 08/13/2014 | $560 | $560 | $0 | - | ||
2. | 01002 | Other | 3314 H | 07/11/2014 | 08/13/2014 | $375 | $560 | $0 | 07/25/2014 | F - Formal Settlement | |
3. | 01003 | Other | 3314 J01 | 07/11/2014 | 08/13/2014 | $0 | $560 | $0 | 07/25/2014 | F - Formal Settlement | |
4. | 01004 | Other | 3395 F01 | 07/11/2014 | 08/13/2014 | $375 | $560 | $0 | 07/25/2014 | F - Formal Settlement | |
5. | 02001 | Serious | 3314 C01 | 07/11/2014 | 08/05/2014 | $2,250 | $3,375 | $0 | 07/25/2014 | F - Formal Settlement |
Investigation Summary
At approximately 12:30 p.m. on January 21, 2014, Employee #1 was assigned to investigate a "vibration" sound in the fan room (Fan S-9) located on the East end of the 7th floor of the building. He de-energized the power source to the fan and installed a lock to the disconnect switch. Prior to entering the room, he ensured that the fan was completely stopped. Employee #1 removed the first two belts by rolling off the pulley without having to loosen the motor. While trying to remove the last of three belts, his left hand finger was caught between the belt and the pulley drive. He was transported to Good Samaritan Hospital and then to Kaiser Permanente Medical Center Los Angeles for medical treatment where his left fourth finger was partially amputated.
Keywords: AMPUTATED, FAN, BELT, FINGER, VIBRATIONS, PULLEY
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 317541134 | Non Hospitalized injury | Amputation | Heating, air conditioning, and refrig. mechanics |