Powered by GoogleTranslate

Inspection Detail

Inspection: 317444164 - Larry Werner Dba Allegany Property Mgt Rentals Llc

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 317444164
Report ID: 0352440
Date Opened: 01/15/2014

Site Address:
Larry Werner Dba Allegany Property Mgt Rentals Llc
37 Boone Street
Cumberland, MD 21502

Mailing Address:
300 Columbia Street, Cumberland, MD 21502

Union Status: NonUnion

SIC:8742

NAICS: 541611/Administrative Management and General Management Consulting Services


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/12/2014

Planning Guide: Safety-Construction

Emphasis: L:Accident, S:Construction (1500-1799)

Case Closed: 04/29/2014


Related Activity
Type Activity Nr Safety Health
Accident 102598091
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $900 $0 $0 $0 $0 $900
Current Penalty $450 $0 $0 $0 $0 $450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260020 B01 03/14/2014 04/16/2014 $450 $900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202721783
Event: 01/14/2014
Two Employees Are Overcomed by Carbon Monoxide and One Dies

On January 13, 2014, Employee #1 and #2 were painting the interior of a 3,000 square foot, two-story rental home that was being rehabilitated to lease. They were painting in a mudroom and a laundry room on the first floor. A 7,000-watt generator was inside the home and being operated to provide power to a portable light. The two employees began working at approximately 8:00 a.m. They were discovered by a family member at approximately 4:00 p.m. laying on the floors of each room. Employee #1 had succumbed to carbon monoxide poisoning and was pronounced dead on the scene. Employee #2 was located and was found unconsciousness. He was transported to a medical center, where he was admitted for carbon monoxide poisoning and hospitalized. Upon entry into the home, rescue workers measured readings of elevated carbon monoxide levels at 80 parts per million (ppm) on the first floor of the home and 172 ppm on the second floor.

Keywords: RESPIRATORY, UNCONSCIOUSNESS, INHALATION, POISONING, PAINTER, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 317444164 Hospitalized injury Poisoning(Systemic) Construction laborers
2 317444164 Fatality Poisoning(Systemic) Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.