Powered by GoogleTranslate

Inspection Detail

Inspection: 317386803 - Bonerts Inc Dba Bonerts Foods

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 317386803
Report ID: 0950631
Date Opened: 03/17/2014

Site Address:
Bonerts Inc Dba Bonerts Foods
3102 W Adams St
Santa Ana, CA 92704

Mailing Address:
2727 S Susan St, Santa Ana, CA 92704

Union Status: NonUnion

SIC:7363

NAICS: 561320/Temporary Help Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/22/2014

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/07/2016


Related Activity
Type Activity Nr Safety Health
Accident 102855665
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $25,200 $0 $0 $335 $0 $25,535
Current Penalty $13,900 $0 $0 $110 $0 $14,010
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 08/25/2014 08/28/2014 $110 $335 $0 09/22/2014 F - Formal Settlement  
2. 02001 Serious 4184 B 08/25/2014 03/18/2014 $12,600 $12,600 $0 09/22/2014 F - Formal Settlement  
3. 03001 Serious 4075 A 08/25/2014 03/18/2014 $1,300 $12,600 $0 09/22/2014 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202558102
Event: 02/26/2014
Employee Amputates Fingertip in Machine

On February 26, 2014, Employee #1 was working in the sanitation area of a facility that manufactured pies and other bakery items. His responsibility included cleaning a dough extruder (Manufacturer Colborne, Model Number 60026-1 and Serial Number 1412-00). The extruder measured at 27 in. length by 30 in. depth by 39 in. width. To clean the extruder, a sanitizer was used and water from a hose that flowed into the machine as the screw of the extruder rotated. The screw needed to be rotating so that water struck all surfaces of the screw. A drain at the bottom with a short pipe allowed the water to flow out of the machine. Employee #1 saw that some dough was stuck at the bottom of the extruder that was not coming loose. He had received training to first turn off the extruder then use an extension tool, a spatula with a 2 ft spatula, to remove any dough that might be stuck to the extruder. The screw was rotating, when Employee #1 placed his left index finger-tip through the pipe and into the bottom drain of the extruder to remove the piece of dough. The rotating screw caught and amputated the fingertip of this index finger. Employee #1 was treated at a medical clinic and then released.

Keywords: ROTATING PARTS, AMPUTATED, FINGER, CLEANING, EQUIPMENT OPERATOR, CAUGHT BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 317386803 Non Hospitalized injury Amputation Janitors and cleaners
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close