Powered by GoogleTranslate

Inspection Detail

Inspection: 317336998 - Tyson Pet Products, Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 317336998
Report ID: 0751910
Date Opened: 09/24/2013

Site Address:
Tyson Pet Products, Inc.
812 3rd Street Nw
Independence, IA 50644

Mailing Address:
P.O. Box 431, Independence, IA 50644

Union Status: NonUnion

SIC:2048

NAICS: 311119/Other Animal Food Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/27/2013

Emphasis: L:Amputate, N:Amputate, S:Amputate

Case Closed: 03/27/2014


Related Activity
Type Activity Nr Safety Health
Referral 200537322 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $4,250 $0 $0 $0 $0 $4,250
Current Penalty $0 $0 $0 $2,000 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100132 D01 10/15/2013 10/18/2013 $2,000 $2,125 $0 10/25/2013 F - Formal Settlement  
2. 01002 Serious 19100212 A01 10/15/2013 10/18/2013 $0 $2,125 $0 10/25/2013 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200536035
Event: 09/14/2013
Employee Partially Amputates Thumb Clearing Drain

At approximately 3:50 a.m. on September 14, 2013, Employee #1, with Tyson Pet Products, Inc., was clearing a drain with a drain cleaning machine (Ridgid Kollman; (Model Number: K-750). Employee #1 was unclogging a floor drain located in the east side packaging area. Employee #1 attempted to stabilize the cable that was in the drain with his left hand and control the foot pedal with his right hand, to advance the cable forward. The cable became stuck and continued to rotate, opening the coils. When the cable cleared a blockage from the drain, the coils shut, pinching Employee #1's rubber glove on his left hand. Employee #1 pulled his hand back and noticed that a portion of his left thumb was missing. Employee #1 attempted to find the amputated portion of his thumb, unsuccessfully. On his way to the nurse's office, Employee #1 stopped to wash his hand off and wrap paper towels around his injured thumb. He was immediately taken to the hospital. A coworker found the missing portion of the thumb and brought it to the emergency room of the hospital. Employee #1 was hospitalized. The amputated portion of his thumb could not be successfully reattached.

Keywords: ROTATING PARTS, AMPUTATED, DRAIN PIPE, PINNED, STUCK, CLEANING, FOOT CONTROL, THUMB, CLOGGED, NIP POINT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 317336998 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close