Inspection Detail
Inspection: 3173002 - Rodriguez Aluminum
Inspection Information - Office: Pr-E-San Juan 0257260
Site Address:
Rodriguez Aluminum
Carr. 845, Km.0 H.3, C. A, Lote 9, Urb. Ind. Cupey
Bo. Cupey Bajo, Rio Piedras, PR 00928
Mailing Address:
Box 607, Rfd #2, Bo. Caimito Bajo, Rio Piedras, PR 00926
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/14/1986
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 07/28/1987
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360109367 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
| Current Penalty | $280 | $0 | $0 | $0 | $0 | $280 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260400 A01 | 08/01/1986 | 08/04/1986 | $280 | $280 | $0 | - |
Investigation Summary
AN EMPLOYEE WAS INSTALLING METAL SHEATHING IN A BUILDING. A 4160-VOLT OVERHEAD POWER LINE WAS LYING ON THE ROOF WHERE HE WAS WORKING. A PIECE OF METAL SHEATHING HE WAS HOLDING CONTACTED THE OVERHEAD LINE, AND THE EMPLOYEE WAS ELECTROCUTED.
Keywords: OVERHEAD POWER LINE, ROOF, ELECTRICAL, ELECTROCUTED, METAL SHEET, E C
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 3173002 | Fatality | Electric Shock | Roofers |