Inspection Detail
Inspection: 317230860 - Home Brew Mart, Inc Dba Ballast Point
Inspection Information - Office: San Diego District Office
Site Address:
Home Brew Mart, Inc Dba Ballast Point
5401 Linda Vista Road, Suite 406
San Diego, CA 92110
Mailing Address:
10051 Old Grove Rd, Ste B, San Diego, CA 92131
Union Status: NonUnion
SIC:2082
NAICS: 312120/Breweries
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/17/2014
Emphasis:
Case Closed: 07/16/2014
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101478907 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 7 | ||||
Current Violations | 7 | 7 | ||||
Initial Penalty | $0 | $0 | $0 | $4,345 | $0 | $4,345 |
Current Penalty | $0 | $0 | $0 | $2,990 | $0 | $2,990 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 3203 A | 06/17/2014 | 07/18/2014 | $560 | $560 | $0 | - | ||
2. | 01002 | Other | 3203 B | 06/17/2014 | 07/18/2014 | $0 | $185 | $0 | A - Amendment | ||
3. | 01003 | Other | 3302 B | 06/17/2014 | 07/18/2014 | $935 | $935 | $0 | - | ||
4. | 01004 | Other | 5162 C | 06/17/2014 | 07/18/2014 | $935 | $935 | $0 | - | ||
5. | 01005 | Other | 5162 E | 06/17/2014 | 07/18/2014 | $0 | $750 | $0 | A - Amendment | ||
6. | 01006 | Other | 5194 E01 A | 06/17/2014 | 07/18/2014 | $0 | $420 | $0 | A - Amendment | ||
7. | 01007 | Other | 5194 F01 | 06/17/2014 | 07/18/2014 | $560 | $560 | $0 | - |
Investigation Summary
At approximately 1:30 p.m. on December 21, 2013, Employee #1, of Home Brew Mart Inc. dba Ballast Point Brewery was closing a valve and disconnecting a hose on a tank containing hot water. Water stored in the hot water tank and kept at 180 degrees Fahrenheit to be used for brewing, cleaning, and sterilization of equipment. Employee #1 connected a hose to one of the valves located on the hot water tank to get hot water for cleaning. After using the hot water to clean the employee turned off the valve manually and disconnected the hose. Employee #1 had not closed the valve completely, so when the hose was disconnected the pressure from the water in the tank caused scalding hot water to spray out onto the employee's upper thighs area. Coworkers that heard the employee yell came to assist him and closed the valve. Employee #1 was hospitalized for approximately six days for treatment of second degree burns to his upper thighs.
Keywords: BURN, THIGH, HOT WATER TANK, VALVE, SPRAYING RIG, TANK, HOT WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 317230860 | Hospitalized injury | Burn/Scald(Heat) | Miscelaneous food preparation occupations |