Inspection: 317144111 - Interlink Inc Dba Precision Plastics Printing Co.

Inspection Information - Office: Santa Ana District Office

 

Inspection Nr: 317144111
Report ID: 0950631
Date Opened: 11/19/2013

Site Address:
Interlink Inc Dba Precision Plastics Printing Co.
3845 E. Coronado St.
Anaheim, CA 92807

Mailing Address:
3845 E. Coronado St., Anaheim, CA 92807

Union Status: NonUnion

SIC:3085

NAICS: 326160/Plastics Bottle Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/28/2014

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/16/2018


Related Activity
Type Activity Nr Safety Health
Accident 102852449
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 4 5
Current Violations 1 4 5
Initial Penalty $14,400 $0 $0 $5,825 $0 $20,225
Current Penalty $14,400 $0 $0 $5,825 $0 $20,225
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/07/2014 03/30/2014 $5,000 $5,000 $0 04/01/2014 J - ALJ Decision  
2. 01002 Other 3203 A 03/07/2014 03/30/2014 $275 $275 $0 -  
3. 01003 Other 3314 G 03/07/2014 03/30/2014 $275 $275 $0 -  
4. 01004 Other 3314 J 03/07/2014 03/30/2014 $275 $275 $0 -  
5. 02001 Serious 3314 C 03/07/2014 03/30/2014 $14,400 $14,400 $0 04/01/2014 J - ALJ Decision  

Investigation Summary

Investigation Nr: 202557310
Event: 11/12/2013
Employee Amputates Two Fingers While Cleaning Grinder

On November 12, 2013, Employee #1, with Interlink Inc. Dba Precision Plastics Printing Company, was cleaning a plastic grinding machine (Cumberland Engineering; Model Number: 1018X; Serial Number: CA025200-05017). For some reason, such as the grinder had become jammed, Employee #1 turned the power off and opened up a cover, which exposed the rotating blade. This blade took about three minutes to stop rotating completely, after the power was turned off. While the blade was still rotating, Employee #1 proceeded to pull out the plastic material around the blade area, and his two fingertips came in contact with the blade. Employee #1 suffered amputation of left middle and ring fingertips. He lost about three quarters to one inch on each finger. He was treated in an emergency room and was not hospitalized.

Keywords: AMPUTATED, FINGER, ROTATING KNIFE, CLEANING, JAMMED, PLASTIC MFG, BLADE, GRINDING MACHINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 317144111 Non Hospitalized injury Amputation Misc. metal & plastic processing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.