Inspection Detail
Inspection: 317009454 - Lucas Electric Company Inc
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Lucas Electric Company Inc
608 Saxby Hill Road
Walterboro, SC 29488
Mailing Address:
218 Bells Highway, Walterboro, SC 29488
Union Status: NonUnion
SIC:7623
NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/27/2014
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 03/10/2014
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102668266 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $650 | $0 | $0 | $0 | $0 | $650 |
Current Penalty | $650 | $0 | $0 | $0 | $0 | $650 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100304 G06VI C8 | 02/06/2014 | 02/10/2014 | $325 | $325 | $0 | - | ||
2. | 01002 | Serious | 19100305 J01II | 02/06/2014 | 02/10/2014 | $325 | $325 | $0 | - | ||
3. | 02001 | Other | 30039 | 02/06/2014 | 02/10/2014 | $0 | $0 | $0 | - |
Investigation Summary
At approximately 10:00 a.m. on September 6, 2013, Employee #1 and Employee #2 were in the attic replacing a damper at a residential home. They had duct taped the insulation to the damper and Employee #2 went downstairs to turn the thermostat to make sure the damper was working properly. Employee #1 was coming from behind the damper unit when Employee #2 heard a zapping sound as if someone was being shocked and he pulled the disconnect switch. Employee #1 was holding a 110v handheld light with a missing ground pin. The light did not have a bulb guard on it and he might have come into contact with the metal portion that held the bulb. There was a red mark on his right arm that might indicate an entry point; an exit point was not determined. Emergency Medical Services responded and Employee #1 died from electrocution.
Keywords: ELEC INSULATION, AIR CONDITIONER, ELECTROCUTED, GROUND FAULT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 317009454 | Fatality | Electric Shock | Heating, air conditioning, and refrig. mechanics |