Inspection Detail
Inspection: 316980606 - Grimmway Enterprises, Inc.
Inspection Information - Office: Bakersfield District Office
Site Address:
Grimmway Enterprises, Inc.
6900 Mountain View Rd
Bakersfield, CA 93307
Mailing Address:
P. O. Box 81498, Bakersfield, CA 93380
Union Status: NonUnion
SIC:2099
NAICS: 311991/Perishable Prepared Food Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/06/2013
Emphasis:
Case Closed: 10/29/2015
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102858339 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $24,750 | $0 | $0 | $0 | $0 | $24,750 |
| Current Penalty | $0 | $0 | $0 | $7,000 | $0 | $7,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 23200001 A | 12/06/2013 | 12/16/2013 | $0 | $3,375 | $0 | 12/13/2013 | F - Formal Settlement | |
| 2. | 02001 | Other | 23200002 A01 | 12/06/2013 | 12/16/2013 | $7,000 | $3,375 | $0 | 12/13/2013 | F - Formal Settlement | |
| 3. | 03001 | Other | 23200002 A B00004 | 12/06/2013 | 12/16/2013 | $0 | $18,000 | $0 | 12/13/2013 | F - Formal Settlement |
Investigation Summary
At about 6:00 p.m. on, or about, August 27, 2013, Employee #1, an electrician with Grimmway Enterprises, Inc., and a coworker (a maintenance mechanic) were working on a roof-mounted swamp cooler. Employee #1 was an active party in the repair of the cooler. The employees had replaced the bolts on the electric motor so that they could place tension on the drive belt that they had replaced. Then, Employee #1 began conducting an amp test on the electric motor. The lockable fuse disconnect door was open, in order to conduct the amp test. The cooler manufacture was Champion Cooler (Date of Manufacture: February 2003; Serial Number: LC65658; Model Number: 6500DD). The causal factor of the accident was that there was a bare energized 480 volt, three-phase wire that Employee #1 came into contact with. Employee #1 died at the scene.
Keywords: ELECTRIC MOTOR, FUSE, REPAIR, ROOF, BELT, ELECTRICAL TESTING, ELECTRICIAN, ELECTROCUTED, WATER TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 316980606 | Fatality | Electric Shock | Electricians |
Translate