Powered by GoogleTranslate

Inspection Detail

Inspection: 316782325 - Rtm Operating Company, Llc Dba Arby'S

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 316782325
Report ID: 0453710
Date Opened: 03/15/2013

Site Address:
Rtm Operating Company, Llc Dba Arby'S
3070 N. Main Street
Hope Mills, NC 28348

Mailing Address:
1155 Perimeter Center West, Atlanta, GA 30338

Union Status: NonUnion

SIC:5812

NAICS: 722211/Limited-Service Restaurants


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/20/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 08/22/2013


Related Activity
Type Activity Nr Safety Health
Accident 100364686
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $11,900 $0 $0 $0 $0 $11,900
Current Penalty $6,300 $0 $0 $0 $0 $6,300
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B01 VIII 06/26/2013 07/01/2013 $6,300 $6,300 $0 I - Informal Settlement  
2. 01002 Serious 19100334 A02 II 06/26/2013 07/01/2013 $0 $5,600 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200361608
Event: 03/09/2013
Electric Shock - Direct Contact with Energized Parts

On March 9, 2013, Employee #1 was brewing a batch of tea using a Bunn Model Number ITCB-DV-series infusion tea and coffee brewer. The brewer was rated at 14 amps from a 120-volt power circuit. Employee #1 noticed that the display screen on the machine stated "tank not full of water." She extended her left hand between the machine and the wall to adjust the flexible water line. As Employee #1 adjusted the water line, her left hand contacted the tea and coffee maker's main power switch. The narrative said that the switch arced or shorted. Employee #1 received an electrical shock and sustained a burn to the back of the middle finger on her left hand.

Keywords: E GI V, ELEC INSULATION, FOOD PREPARATION, ELECTRICAL, ELECTRIC SWITCH, HEATER, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316782325 Non Hospitalized injury Electric Shock Supervisors, food preparation & service occupation
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close