Inspection Detail
Inspection: 316720770 - Porterville Unified School District
Inspection Information - Office: Fresno District Office
Site Address:
Porterville Unified School District
900 W. Pioneer Ave.
Porterville, CA 93257
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:9411
NAICS: 923110/Administration of Education Programs
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: LocalGovt
Safety/Health: Health
Close Conference: 12/20/2012
Emphasis:
Case Closed: 01/29/2013
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101088201 |
Investigation Summary
On November 29, 2012, Employee #1, a 27-year-old male, Employee #2, a 26-year-old male, Employee #3, a 44-year-old female Employee #4, a 45-year-old female, Employee #5, a 53-year-old female, Employee #6, a 54-year-old female, Employee #7, a 41-year-old male, Employee #8, a 57-year-old male, Employee #9, a 65-year-old female, Employee #10, a 59 -year-old female, Employee #11, a 41-year-old female, Employee #12, a 51-year-old female, Employee #13, a 54-year-old female, Employee #14, a 49-year-old female, Employee #15, a 42-year-old female and Employee # 16, a 45-year-old female with Porterville Unified School District were involved in a catastrophic event causing the sixteen employees to be transported to three medical facilities after the release of three hundred pounds of R-507 refrigerant was released into Porterville Unified School District's Central Kitchen. The release occurred in the kitchen 47,000 cu. ft. cold room when the facility was not occupied. At first, Employee's entering the cold room did not detect or notice anything wrong, however as the refrigerant migrated from the cold room into the warmer cooking area, it expanded and filled the kitchen. Employee's in these warmer areas were able to detect a sweet smell and then began experiencing upper respiratory and eye irritations, which triggered an evacuation of the facility. The refrigerant release was found to be the failure of the air handler's evaporator coil that was abraded by an electrical conduit rubbing against it. During the installation of the air handler a hold-down clip that secures the conduit was not installed and the defect occurred under a cover that normally would not be removed for normal maintenance.
Keywords: EYE, LEAK, RESPIRATORY, GAS, REFRIGERANT, RESPIRATORY TRACT, CHEMICAL VAPOR, CHEMICAL
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
2 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
3 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
4 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
5 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
6 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
7 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
8 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
9 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
10 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
11 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
12 | 316720770 | Non Hospitalized injury | Asphyxia | Food batchmakers | ||
13 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
14 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
15 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported | ||
16 | 316720770 | Non Hospitalized injury | Asphyxia | Occupation not reported |