Inspection Detail
Inspection: 316672377 - Kk Mechanical, Inc.
Inspection Information - Office: Van Nuys District Office
Site Address:
Kk Mechanical, Inc.
147 N. Brent St.
Ventura, CA 93003
Mailing Address:
1858 West 5150 South, Roy, UT 84067
Union Status: NonUnion
SIC:1711
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/10/2014
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/04/2014
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 102788734 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $840 | $0 | $840 |
Current Penalty | $0 | $0 | $0 | $840 | $0 | $840 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 1509 A | 04/11/2014 | 04/30/2014 | $420 | $420 | $0 | - | ||
2. | 01002 | Other | 3395 F03 | 04/11/2014 | 04/30/2014 | $420 | $420 | $0 | - |
Investigation Summary
At approximately 7:30 a.m. on November 4, 2013, Employee #1, with Kk Mechanical, Inc., was installing new plumbing in a new six story hospital building. Employee #1 suffered from gastrointestinal bleeding due to an acute alcoholic gastritis. Employee #1 and his coworker were working in the basement, back filling trenches. Employee # 1 and the coworker started working at approximately 6:30 a.m. The coworker observed that Employee #1 drank six or seven cups of water and stated that Employee #1 complained that he smelled bleach in his water cup. Employee #1 was hospitalized, possibly for stomach pains and/or internal bleeding. The investigation concluded that Employee #1 suffered from gastrointestinal bleeding due to an acute alcoholic gastritis.
Keywords: INSTALLING, LOSS OF BLOOD, BLEACH, TRENCH, PLUMBING, POISONING, STOMACH
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 316672377 | Hospitalized injury | Poisoning(Systemic) | Plumber, pipefitter and steamfiter apprentices |