Powered by GoogleTranslate

Inspection Detail

Inspection: 316668003 - Kelcole Mfg. Inc., Dba Consolidated Overhead Door

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 316668003
Report ID: 0950643
Date Opened: 10/01/2012

Site Address:
Kelcole Mfg. Inc., Dba Consolidated Overhead Door
813 Romero Cyn. Rd.
Santa Barbara, CA 91308

Mailing Address:
30 S. Calle Ceser Chavez #A, Santa Barbara, CA 93123

Union Status: NonUnion

SIC:1799

NAICS: 238190/ Other Foundation, Structure, and Building Exterior Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/01/2013

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/31/2015


Related Activity
Type Activity Nr Safety Health
Accident 102784444
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 4
Current Violations 1 3 4
Initial Penalty $18,000 $0 $0 $5,750 $0 $23,750
Current Penalty $3,845 $0 $0 $1,830 $0 $5,675
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 342 A 03/04/2013 03/06/2013 $1,500 $5,000 $0 03/25/2013 F - Formal Settlement  
2. 01002 Other 1509 A 03/04/2013 03/21/2013 $165 $375 $0 03/25/2013 F - Formal Settlement  
3. 01003 Other 3395 F03 03/04/2013 03/21/2013 $165 $375 $0 03/25/2013 F - Formal Settlement  
4. 02001 Serious 3324 B 03/04/2013 03/21/2013 $3,845 $18,000 $0 03/25/2013 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202656930
Event: 09/07/2012
Employee Suffers Head Injuries from Falling Door

At approximately 8:10 a.m. on September 7th, 2012, Employee #1 was adjusting and setting up a horizontal gate motor. Employee #1 removed upper positive clamp stops while adjusting the gate settings. As Employee #1 was completing this task, the gate came out of the upper roller, and as he attempted to roll the horizontal gate back into to the roller, was struck by the gate. Employee #1 was transported to a local hospital and was hospitalized for two days.

Keywords: HEAD, HEALTH CARE FACILITY, ENGINE, STRUCK BY

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316668003 Hospitalized injury Fracture Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.